Table 1 : Permissible wind pressure (positive) loads in kN/m2 – deflection limit span /f

 NOTE: Please view LANDSCAPE on mobile phone 

Sheet ThicknessWeight kg/m2Span ConditionSpan mm
14001600180020002200240026002800300032003400
0.50mm4.78single2.621.981.521.100.82
double1.951.561.271.060.890.77
multi2.391.911.561.301.100.940.82
0.70mm6.22single4.033.052.141.541.150.88
double3.242.592.111.761.481.271.100.960.80
multi3.983.182.602.161.831.571.250.990.80
0.90mm8.42single6.344.643.212.321.721.321.030.82
double5.254.163.382.802.362.011.741.431.160.950.79
multi6.475.134.173.462.922.301.801.431.160.950.79

 

Table 2 : Permissible wind suction (negative) loads in kN/m2 – deflection limit span /150

Sheet ThicknessWeight kg/m2Span ConditionSpan mm
14001600180020002200240026002800300032003400
0.50mm4.78single2.251.911.491.200.980.75
double2.001.601.301.090.920.79
multi2.451.961.601.341.130.970.84
0.70mm6.22single4.173.152.471.831.361.040.81
double3.182.532.061.721.451.241.070.940.80
multi3.903.112.542.111.791.531.250.990.80
0.90mm8.42single6.334.793.522.541.891.441.30.90
double5.264.163.382.802.362.021.741.431.60.950.79
multi6.485.144.183.472.922.301.801.431.160.950.79

 